Description The program allows the mass maintenance of fields for the QM order andthe individual QM order in the inspection setup of the material master. The following functions are supported:
- Assigning a QM order
- Deleting assignment of a QM order
- Replacing previous QM order with assignment of a new QM order
- Setting or canceling the indicator for the individual QM order
You can either enter the new QM order to be assigned on the initialscreen, or use the function for creating a QM order. You can access the following additional functions from the environment> menu on the list screen:
- Create QM order
(A new QM order is created that is not taken into account in theassignment).
- Change QM order
- Display QM order
Output The program creates a list with material-inspection type combinationsthat support the functions listed above. Example To calculate inspection costs in QM, you want to assign a new QM orderto all materials in plant 0001 with inspection type 01. Proceed as follows: Enter plant 0001 > and inspection type 01 > as selectioncriteria Edit the standard values for the new QM order (account assignment andadditional data). Choose the function for creating a new QM order. Execute the report program. A worklist is created with material-inspection type combinations. Choose Select all>. Choose Edit -> Assign QM order>. Save the data. The new QM order is created and assigned to all the material-inspectiontype combinations you selected.
|