Purpose This report changes the setting of the standard conversion groups forthe Quantity Conversion Interface (QCI). In Customizing for theIndustry Solution Oil and Gas (Downstream)>, you can either setthe field CHLQ in table OIB01 to 1 or leave it blank. If you set thefield to 1, the system does not call the external API C codes. If youleave the field blank, the system calls the external API C codes. Youcan carry out this setting by choosing HPM -> Petroleum MeasurementStandards -> Quantity Conversion Interface (QCI) Configuration -> DefineConversion Group and External Function Module Settings.>Integration You execute the report if no API C codes are installed for theapplication test (1980 version of the API C codes). Select the following radio buttons and execute the report:
- Check API c-code Installation >
- Internal QCI conversion >
After you execute the report with this selection, the system sets thefield OIB01-CHLQ in the conversion groups below to 1. Now you can startthe application test without the API C codes being installed. To use the API C codes in the same client, you use the standardconversion groups. In this case, select the following radio buttons andexecute the report:
- Do not check API c-code Inst. >
- Call API c-code >
Prerequisites You have a new installation of IS-Oil, or you want to carry out anupgrade test of IS-Oil. Features The report changes the settings of the following conversion groups:
- 234A
- 234B
- 234C
- 234D
- 56A
- 56B
- 56C
- 56D
- 534A
- 534B
- 534C
- 534D
- 596A
- 596B
- 596C
- 596D
|