SAP Parameter rdisp/autoabaptime - Specifies the time cycle in seconds SAPMSSY6 is running

Parameter
rdisp/autoabaptime

Short text
Specifies the time cycle in seconds SAPMSSY6 isThis parameter controls the interval at which SAPMSSY6 (screen 1100)is executed.A value of 0 deactivates automatic execution. With a value of n <(>><)>
0,the program is periodically run in the background every n seconds(for information about the unit, see below).

Work area
Dispatcher and task handlerThe value can be specified with or without a time unit. If you donot specify a time unit, the system uses seconds as the unit.Alternatively, you can specify M for minutes or H for hours. Therecan be spaces between the value and the unit.
Examples
300 300 seconds
2 M 2 minutes
3H 3 hours

Default value
300 seconds

Who is allowed
The customer

Limitation for os
none

Limitation for db