Parameter icm/max_socketsMaximum number of (simultaneously) open sockets of the ICM or SAPWeb Dispatcher.Each connection can require one or two sockets, depending on thetype of connection:
- The SAP Web Dispatcher always requires two sockets for a
connection
- The ICM in the SAP Web AS requires two sockets per connection if
it is communicating with an SAP J2EE Engine.Work area Internet Communication Manager Parameter unit Number Default value 2048 Who is allowed The customerThe administrator can usually configure the maximum number ofsockets that a process can have open in parallel. See also youroperating system documentation about this topic. Limitation for db None icm/max_conn> the maximum number of sockets must besignificantly greater than the maximum number of connections,so that the limiting of the possible connections is performedby icm/max_connValid_values Integer
|