Solution : https://service.sap.com/sap/support/notes/956487 (SAP Service marketplace login required)
Summary :
When releasing maintenance (PM) or service orders in change mode via IW32, the system fails to generate inspection lots, despite the association of the order type with an inspection type. Relevant SAP elements include T399X configuration and PM/QM integration. The issue stems from a programming error activating during task list generation in order change scenarios, where a dummy operation is present.
Key words :
general maintenance task list, pm/qm linkage, test equipment management, dummy operation exists, change order reason, relevant order type, maintenance inspection lot, maintenance order, inspection lot, change mode
Related Notes :
1067900 | VA01: No inspection lot created for PM order/service order |
916614 | IW34: No inspection lot created for the PM or CS order |
901032 | IW32: Inspection lot is not created during the release |
876054 | No inspection lot from PM/CS order after you delete ref obj |
694469 | No inspection lot for maintenance/service order |
592808 | Test equipment management: FAQ and "What to do, when" ... |