SAP Note 93442 - CIP2: No update due to termination RU085

Component : Plant Data Collection -

Solution : https://service.sap.com/sap/support/notes/93442 (SAP Service marketplace login required)

Summary :
SAP Note addresses an issue where entries in the RUECK table are not updated during PDC message processing (Transaction CIP2), potentially causing a runtime error. This issue originates from terminations in cost calculations, specifically outlined by message RU085. The problem is exacerbated if modifications from SAP Note 83590 (dealing with parallel updates from Release 3.1H) or Note 91894 (relevant to Releases 3.0F to 3.1H for error record handling) are not applied. The prescribed solution involves storing error records for affected tasks, allowing for reprocessing of improperly handled PDC messages. For further details or potential concerns, reference to Note 74833 is recommended for additional insights into termination message resolution.

Key words :
additional key words cip2, reprocessing incorrect pdc messages, incorrect records repeatedly, determining actual costs, entries remain unprocessed, pdc error records, pdc messages, transaction cip2, error records, runtime error

Related Notes :

133898Termination during confirmation or scheduling order
99121CO16: RU422 because of incomplete Note 93442
93866PDC:Completion confirmtn data processd incompletely
91894CIP2, CIP3, CIP4: no finish when blocking
83590Performance PDC upload PP/PM/PS: Parallelization
74833Wrong actual costs or termination in confirmation