Solution : https://service.sap.com/sap/support/notes/747317 (SAP Service marketplace login required)
Summary :
From Release 4.6, users encountered issues with maintaining configurations in VOE2 and VOE4 due to restrictive settings within the client’s environment. Analysis via SE11 reveals the EDPAR table’s class as C, indicating customization restrictions. For investigating table settings' modification capacities, transaction SM31 checks can be implemented against the T000 table to confirm client-specific configuration adjustment limitations. Information specific to altering productive systems' configurations for VOE4 are detailed in SAP Note 135028; for non-productive systems, refer to Note 356483. Key transactions and table references include EDPAR, EDSDC, SM31, and VOED.
Key words :
symptom problems maintaining voe2, client-dependent objects, client role, terms edpar, voed solution, table edpar, delivery class, customizing table, transation sm31, table t000
Related Notes :
356483 | Customizing: Current settings in the test system |
135028 | Transfer IMG activity to current setting |