Solution : https://service.sap.com/sap/support/notes/732471 (SAP Service marketplace login required)
Summary :
When initiating Transaction MB51 or RM07DOCS with the "Short Docs" parameter, users face performance issues or TIME_OUT errors especially with multiple active archive information structures set for MM_MATBEL in the archive system. This is due to the design flaw where the system selects a non-specified active archive info structure, leading to inefficient data access and processing. To rectify, a new "Archive Infostruct" parameter helps specify the relevant structure directly on the selection screen, improving runtime efficiency and error handling if field restrictions are incompatible with the available structures. Correction implementations include new error messages and the option to save the chosen structure for future sessions.
Key words :
symbol text 021 reading mm documents 022 reading short documents 023 prepare list output 024 read mm doc, archive 025 read archive info records 026 select, system issues warning message m7 432 telling, multiple active archive info structures exist, multiple active archive information structures, active archive info structure exists, active archive info structure correct, existing active archive info structures, system issues error message q6 012, active archive information structure existed
Related Notes :
901394 | Termination in /BEV1/NEMB51 |
609921 | MB51: Materials not transferred from search help |
599966 | MB51: Use of the archive information system instead of MARI |