Summary :
During the ACT_30D phase, error DT609 occurs when activating reconciled technical settings from the SPDD phase. This stems from a bug in the program RADTBTTS. To resolve, modify RADTBTTS as outlined before starting SPDD. Post-error, repair the source code and modify table settings via transaction SE13, setting them to the correct data class and size category. Repeat the SPDD adjustment and ACT_30D phase if necessary. Ensure correct attributes are maintained to prevent DT617 and DT616 errors.
Key words :
additional key words dt609, affected technical settings online, source code listed, choose settings -> reset, maintain suitable values, start transaction se13, activating technical settings, technical settings listed, prerequisites program error, starting transaction spdd