Solution : https://service.sap.com/sap/support/notes/372359 (SAP Service marketplace login required)
Summary :
The SAP Note addresses an issue where the constructor for CL_GUI_DOCKING_CONTAINER might trigger a CNTL_ERROR exception if the size parameters assigned exceed recommended limits. This is due to the RATIO parameter in the control framework, where only values between 5% and 95% are viable to maintain screen usability. Values outside this range disrupt the docking container's functionality, leading to errors. Implementations should ensure to keep the RATIO parameter within the specified bounds to avoid this exception.
Key words :
additional key words control framework, cl_gui_docking_container supplies exception cntl_error, exception mentioned, docking container, screen expansion, parameter ratio, remaining screen, constructor, prerequisites, determined
Related Notes :
373592 | Expansion of docking containers in percent: Problems |