SAP Note 308022 - FAQ: QCI - Quantity Conversion Interface

Component : Quantity Conversion Interface -

Solution : https://service.sap.com/sap/support/notes/308022 (SAP Service marketplace login required)

Summary :
This SAP Note provides solutions to FAQs regarding the Quantity Conversion Interface (Q CI) in IS-OIL / IS-MINE solutions, advising only applicable instances where both solutions are installed. Key issues addressed include changing a material’s conversion group used in production, executing plant-to-plant transfers with differing conversion groups, and necessary customizations in unit measure tables. Additionally, it tackles quantity conversions for specific product types, activating standard transactions for natural gas processes, and implementing specific rounding routines in the system. Directions to resolve errors, adapt to new configurations, and enable custom specific adjustments are detailed. It emphasizes reading related notes for comprehensive guidance.

Key words :
3rd party supplier solutions supporting calculations, sap certified integration partners provide, 3rd party quantity conversion solutions, astm d1250-04 qunatity conversion standard, execute astm d1250-04 conversion groups, sap-certified integration solutions, sap certified integration solutions, measure tables   t006 required, legacy astm d1250-80 standard, solution                              faq & answers                                                          1q

Related Notes :

970603QCI - Supporting the standard ASTM D 1250-04
954553QCI: New standard API 2004
927099IS-OIL special customizing flag for OIB04 & OIB01 Switch BC
822435QCI calculator to consider settings from CUNI(T006) only
762971QCI: Report to Set Conversion Groups for IS-Oil Quick Test
713382QCI: How to set up the QCI for natural gas conversions?
652834Additional Quantity Handling: Manual Changes and Effects
621262Customizing of dimension ID in an IS-Oil system
619060QCI: New RFC server installation guide
619057QCI: External function calls using the CALL SYSTEM command
585290QCI: New BAdI for customer-specific export param. handling
580208Missing ISO-Codes for Oil & Gas systems
577190QCI: Enhancements with SAP Oil & Gas 4.6C Service Pack 2
571792QCI: Definition of UoM conversion factors
568867QCI: Manual entry indicator and external applications
568587QCI: Definition of new customer specific parameters
553794QCI: Detailed documentation for Hydrometer Indicator
545432QCI:Quantity Conversion Interface - detail information
540970QCI: Compliance with Measurement Standards
534776Thermal expansion coefficient not passed to QCI
520356Rounding of test density value in QCI dialog box
505166New BADI methods for existing QCI BADI
487031Quantity conversion interface(QCI): enhancements&corrections
485876Performance of Report ROIB_COPY_DEF
410309QCI conversion parameters incomplete in method call
384536Corrections within the QCI (Quantity Conversion Interface)
363393Corrections within Quantity Conversion Interface (QCI)
351661Small corrections within the Quantity Conversion Interface
351126Error message O3031 - QCI - Calculations not possible
334598Additional qtys: HPM dialog box in new transactions
325772QCI: Example function group (Asphalt, LPG)
315496Dimensionless uom & QCI (Quantity Conversion Interface)
170087Plant-to-Plant transfers with different conversion groups
103003API & AGA C-Code Routines: Availability, Parameter Ranges
83265IS-Oil Validation without Ext. Quantity Conversion Routines
67868IS-Oil: API C-Code Changes: Rounding Rules/Range Extensions
39620Quantity calculations and rounding to n decimals
38865WO3074: man.qty. affects other qtys. that have been calc.