Solution : https://service.sap.com/sap/support/notes/1561940 (SAP Service marketplace login required)
Summary :
After activating an Enterprise Extension in SFW5, users may face execution issues where internal, classical BAdIs do not execute and certain BC-Sets (e.g., EA-..-AKH, EA-..-IMG, EA-..-MENU) remain unpacked. The underlying problem may lie in the switch in table TBE11 being inactive, usually activated through the SFW_CHECK_EA_SWITCHES implementation which can fail due to issues noted in SAP Note 1548839. To mitigate, ensure SAP Note 1548839 is implemented and run ENHS_BADI_ANALYZE_GENERATE_ALL in GENERATE-mode before extension activation. If issues persist, apply this note's correction via SNOTE with the SFWTOOLS package, then re-run SFW_CHECK_EA_SWITCHES with ACTIVATE option checked.
Key words :
business transaction events, generate-mode prior, select checkbox activate, execute report sfw_check_ea_switches, implementation sfw_check_ea_switches provided, terms switch framework, switch framework, report enhs_badi_analyze_generate_all, enhancement framework, enterprise extension
Related Notes :
1548839 | Transport of Enhancement Spots cause BAdI impl. to be lost |
1049251 | Activate Enterprise Extensions in the switch framework |