If you need to determine the appropriate IGS version for your Web AS, note that as of 02.02.2011, standard sources like the Maintenance Optimizer or SP Stack Application might display inaccurate IGS versions for products using 7.11 kernel or similar. This SAP Note guides correct IGS installation per various WAS kernels: WAS 6.40 requires IGS 640; WAS 7.0* (700, 701, 702) requires IGS 700; WAS 7.1* demands IGS 710; WAS 7.2* needs IGS 720; WAS using 7.20_EXT kernel should use IGS 720_EXT. Reference SAP Note 931900 for identifying your current IGS patch level.