During a Unicode Conversion, executing report UMG_ADD_DOWNTIME_STEP, which calls UMG_CHECK_APPLICATION_TABS, may result in errors or warnings stating that certain tables are not empty. Address these based on each table's specific guidance. For TICNV, confirm no ongoing incremental conversion, referencing System Copy Guide's export prerequisites. For HRPADNN, consult note 573044 and execute RHADATACHECK. For GRRT, refer to note 837184 and perform RGRDLINC. For VBDATA, VBHDR, and VBMOD, fix or clear canceled/pending updates as per note 67014 and execute RSM13002.