Solution : https://service.sap.com/sap/support/notes/1396999 (SAP Service marketplace login required)
Summary :
During the configuration of Diagnostics in SAP Solution Manager, issues may arise related to SOAP Runtime functions leading to ICF and internal server errors ("ICF Error when receiving the response: ICM_HTTP_CONNECTION_FAILED" and "HTTP Code 500 : Internal Server Error"). These occur because the ABAP stack cannot properly communicate with the Diagnostics Setup Web Service on the Java stack. Problems usually involve incorrect URL generation for SOAP communications. To resolve this, verify the Service URL via the SOAMANAGER, ensuring the logical port and transport settings are accurately configured. If discrepancies persist, check for the latest updates of LMSERVICE and refer to defaultTrace logs for deeper analysis.
Key words :
transaction soamanager > service administration > single service configuration, calling soap runtime functions, diagnostics configuration fails due, diagnostics setup web service, solution manager setup, internet communication framework, unsupported xstream found, logical port configuration, url generation reason, logical port entry
Related Notes :
1297849 | Root Cause Analysis URL generation |