SAP Note 12260 - File I/O error when accessing TemSe object

Component : TemSe (Repository for temporary sequential objects) -

Solution : https://service.sap.com/sap/support/notes/12260 (SAP Service marketplace login required)

Summary :
Errors occur when accessing TemSe objects such as spool data and background logs, indicated by a File I/O error (F3V) in the SysLog. The F3V error appears during read/write file access although files seemingly exist. Likely cause: the global directory is shared via NFS across multiple application servers, and one machine might face temporary NFS access issues. To resolve, check and rectify NFS access from the impacted application server. Details about the error code xx can be found in the errno.h file on the concerned machine.

Key words :
f3v error xx occurs, affected application server andcorrect, error code xx, syslog report f3v, symptom errors occur, access temse objects, problems withnfs access, global directory reason, global directory, application servers

Related Notes :

504952Composite note regarding spooling and printing