Programme SAP RNUX3010 - IS-H 4.01 XPRA for Initialization of EDI NUMC Fields

Description
For IS-H Release 4.01, the program sets the initial value '0' for allEDI message numbers and file numbers that were empty in previousreleases.
Only the tables NC301S and NC301I are affected. This initial valuecannot occur in any other tables.
The program is not relevant for hospitals in which the EDIfunctionality is still to be implemented.
In all other hospitals you should run the program before commencingnormal production operation. Otherwise individual table entries cannotbe correctly found nor assigned.
If problems arise during the release upgrade, the upgrade can becontinued. However, you must run this program again afterwards.
You can execute the program again at any time.

Output
The program outputs a log of the actions performed by client. Dependingon the EDI procedure used in certain clients, actions may not bepossible or necessary.
In such cases, the following message is issued:
No conversion necessary. Nothing to do in client xxx
If existing data in tables was changed, the program lists the number ofrecords changed per table field.
Client xxx 0000000123 LF301D updated
Client xxx 0000000123 LF301 updated
Client xxx 0000000123 LF301REF updated