Programme SAP RNCEDIU1 - IS-H: Release EDI Messages Manually

Description
The report IS-H: Release EDI Messages Manually (RNCEDIU1)creates a list of EDI messages that have not been transmitted. You caneither set or cancel the lock indicator for a message in this list. Aslong as the lock indicator remains set, the file creation programcannot write the message to an EDI file.
This affords, in particular, a check mechanism for CCPS data exchangein Singapore.
This program is officially released for case-related EDI proceduresonly.

Precondition
To execute this program you require authorization S_PROGRAM with actionSUBMIT for the report group N_U3_UW. You also have to haveauthorization N_EINR_REP for the desired institution and for the reportIS-H EDI: Display Data Collection Point-Insurance ProviderAssignment (RNC301U1). If you do not have authorization for a part
icular institution, the system does not output the data of theinstitution concerned.
For the lock indicator to be correctly used, you must have selected theManual Release Control for EDI Messages indicator in the IMGactivity Activate EDI Procedure to prevent change messages frombeing automatically sent as soon as they are created.
You'll find more information about this in the IS-H ImplementationGuide under SAP Healthcare - Industry-Specific Components forHospitals -> Communication -> Electronic Data Interchange
-> Activate EDI Procedure.

Output
The report creates a list containing all message details. The followingdetails are output:

  • Lock indicator for each EDI message.

  • Control data for each EDI message (content of the table IS-H EDI
  • Status Data Management (NC301S)).
    You can cancel or set the manual lock indicator again for the selectedmessages.
    Note that you have to cancel the lock indicator per message type inchronological order. You cannot release newer messages if oldermessages are still flagged for manual checking.