Description The report RLWMPPC5 (transaction LX43>) checks theconsistency of the control cycles>. This means thatyou can easily assess inconsistencies in the definition of the controlcycles, the prodution supply area and the correspondingreservations>. First, a check is carried out whether the storage location >/plant combination from the production supply area> is allowed. If no corresponding entry isavailable in table T320, the traffic light is switched to 'red', and anerror text is output additionally. Then, a check is carried out whether the staging indicators in thecontrol cycle match the staging indicators for the reservations.
- If all reservations have the same staging indicator as the control
cycle, then the traffic light is set to 'green'.
- If all reservations have the same staging indicator, but this does not
match the indicator for the control cycle, then the traffic light isswitched to 'yellow'.
- If the staging indicators for the reservations for a control cycle
differ, then the traffic light is set to 'red'. A red traffic light which results from the storage location/ plantcheck is not overridden.
|