Parameter rdisp/max_priv_time Short text Maximum hold time for work processes in PRIV modeIf the number of work processes that can be in PRIV mode(parameter rdisp/wppriv_max_no> ) exceeded, the work process thathas been in PRIV mode for the longest time and exceeds this timelimit, is terminated.A work process is in PRIV mode if it must allocate memory local toThis work process is then not available for other users (see alsoztta/roll_extension> ).The Value 0 means "infinite".Work area DispatcherThe value can be specified with or without a time unit. If you donot specify a time unit, the system uses seconds as the unit.Alternatively, you can specify M for minutes or H for hours. Therecan be spaces between the value and the unit. Examples Default value 600 ( 10 minutes ) Who is allowed The customer Limitation for os None Limitation for db Nonerdisp/wppriv_max_no>ztta/roll_extension>Valid_values Character string |