Parameter gw/netstat_once Short text Get own IP addresses only during startup Parameter description When you start up the gateway, all of your own IP addresses aredetermined with the 'netstat' command and saved internally. This isnecessary to be able to establish whether a program must be startedlocally or remotely. There are high-availability solutions in which IP addresses can wanderfrom one host to another. That is, the entries that are read when thegateway was started may no longer be valid. In this case, the currentconfiguration must always be read when performing the test for a localIP address. To activate this mechanism, this profile parameter must beset to 0. A default value of 1 means that the configuration is read only onceduring start up. Work area Gateway Parameter unit Boolean value (0/1) Default value 1 Who is allowed Customer Limitation for os None Limitation for db None Other parameter gw/netstat> gw/alternative_hostnames>Valid_values 0 / 1 |