SAP Note 783499 - Incorrect framework synchronization

Composant : General Parts -

Solution : https://service.sap.com/sap/support/notes/783499 (Connexion à SAP Service Marketplace requise)

Résumé :
This SAP Note addresses issues where the system alternates between using the SAPUP50R report and classes derived from CL_HRPA_INFOTYPE_CONTAINER to manage infotype records, causing errors. The key error indicated is PBAS_SERVICE 039, where data record groupings are incorrect due to the CCURE PC_UI indicator in the T77S0 table not being set. The resolution involves setting this indicator and executing reports RPUFACECPRFN, RPUFACEVIEKN, and RPUFIXDS to adjust and correct related data fields and features. Additionally, implementation of program corrections and Note 845592 is required to enable proper maintenance of the indicator.

Mots Clés :
system issues error message pbas_service 039, rpufaceviekn report creates correct occupancies, t582a-cprfn rpufaceviekn, write infotype records, ccure pc_ui indicator, pshrd-gprvl field, attached program corrections, ivwid feature rpufixds, sapup50r report, ivwid feature

Notes associées :

1447867Indicator CCURE/PC_UI in the table T77S0
1046865SAP ERP 6.0 SP Stack 10 (07/2007) Release Information Note
845592Incorrect framework synchronization - Retroactive accounting
844998PU00: Termination when deleting a personnel number