SAP Note 410173 - Duplicate components after conv.

Composant : Requirements Planning/Planned Order - PP-DS / Production and Process Order

Solution : https://service.sap.com/sap/support/notes/410173 (Connexion à SAP Service Marketplace requise)

Résumé :
This SAP Note addresses a defect in the conversion of planned orders to production or process orders within APO and R/3, leading to duplicated components especially when handling by-products or co-products. The issue originates from the reassignment of temporary line item numbers post transfer to APO, preventing appropriate mapping. The resolution involves altering the source code to ensure component assignments in APO use the BOM item instead of the external R/3 key. Modifications also include updating the interfaces of /SAPAPO/RRP_APPEND_COMPONENTS and /SAPAPO/RRP_APPEND_OUTPUTS with an additional optional parameter IV_MAP_BOMID_ONLY. Implementation of SAP Note 419958 is recommended for complete resolution.

Mots Clés :
-product manufacturing order aposfc planned order conversion mapping, iv_map_bomid_only type /sapapo/boolean default gc_false, additional key words production order conversion, line item numbers assigned, planned order, converting planned orders, functions    /sapapo/rrp_append_components, optional import parameter, implement note 419958 subsequently, /sapapo/rrp_append_outputsrequire

Notes associées :

814002R/3->APO: Component not deleted
739248Composite note: Problems with the component mapping
595998APO->R/3 Component duplicated in R/3 and APO
524371Incorrect order reservations in APO
430698Order transfer causes COM error (return code 152)
419958Planned order conversion or failure of order transfer