Solution : https://service.sap.com/sap/support/notes/796763 (SAP Service marketplace login required)
Summary :
In cases of data upload to the Persistent Staging Area (PSA) in SAP BW environments, an issue arises where the RSMONICDP table encounters excessive locking, cumulatively initiating locks about 100 times per data package. This issue is identified as a defect in programming. As remedial measures, the following SAP BW versions require specific support packages: BW 2.0B (Support Package 40), BW 2.1C (Support Package 32), BW 3.0B (Support Package 26), BW 3.10 (Support Package 20), and BW 3.5 (Support Package 11). These updates, detailed further in upcoming SAP Notes, are necessary to resolve the locking issue.
Key words :
sapbwnews bw support package 11 netweaver'04 stack 11, 10 content import support package 20, 0b import support package 40, 1c import support package 32, 0b import support package 26, 50 import support package 11, 1 content support package 20, persistent staging area, 0b support package 40, 1c support package 32
Related Notes :
857918 | P28: P4: MON: High number of enqueue rejects in SM12 |
763338 | SAPBWNews BW Support Package 11 NW'04 stack 11 RIN |
723262 | SAPBWNews BW 3.1 SP Content 20 |
723257 | SAPBWNews BW 3.0B Support Package 26 |
617459 | SAPBWNews BW 2.1C Support Package 32 |
601013 | SAPBWNews BW 2.0B Support Package 40 |